Dialogs

'Change entry' Dialog

You open this dialog by double-clicking an item in the data table of the following reports:

CIE Report

Dot gain report

Density report

PV CIE report

PV dot gain report

This dialog lets you change the items listed for the data sets in the open series. The dialog contains the items of the data set used to display it. This data set is enabled in the data table (orange back­ground).

File name

The name of the original color data file appears in this box. You cannot change this name.

Location

The path of the original color data file appears in this box.

Click the button with the three dots to set a different location with the "Open file" dialog.

Status

The status lets you define how the current data set will be handled in the long-term analysis. There are three status options:

"Enabled": The data are compared with the reference data during the long-term analysis. The box is enabled (ticked) in the list.

"Disabled": The data are not to be included in the long-term analysis but are to remain in the current series. The box is disabled (no tick) in the list.

You can delete the data set from the series by clicking "Remove".

"Reference": A selected process standard (it has "P" as its "ID") is set by default as the reference data set.

If you disable this process standard, the first data set in the list below is then automatically used as the reference.

You cannot change the status of a reference data set. You must first define another data set as the reference, then the status of the previous reference data set automatically switches to "Enabled". However, the ID remains the same.

Date

Date the data file was saved on. You can change the entry by overwriting it or using the arrow keys. The format is set: Year - Month - Day.

Time

Time the data file was saved at. You can change the entry by overwriting it or using the arrow keys. The set format is: Hours : Minutes : Seconds.

Comment

You can type any comment you wish or modify an existing one to have a better overview of the dif­ferent data sets.

"Update process standard

Use this function to change the current process standard. Proceed as follows:

1.Select the printing standard you want in the "Process standard" main function.

2.Double-click the first row in the data table (indicated by "P" for process standard).

3.Check the "Update process standard" box in the "Change entry" dialog and click "OK".

The dialog closes and the relevant reference values are refreshed in the data table.

Buttons

Click "OK" to confirm your settings for the current data set and copy it to the list. The dialog closes.

Click "Cancel" to close the dialog without changing the settings for the current data set.

You delete the current data set from the series by clicking "Remove".

The item is removed from the list. The IDs of the subsequent data sets are changed accordingly.