"Trapping" Option

"Trapping" is a term that is widely used in the graphic arts industry. This term refers to the spreading and choking performed between two abutting colors. Trapping is used to avoid "flashes", in other words, unwanted white lines or color margins at color transitions that are the result of register errors in printing. The trapping option lets you add thin lines ("trap lines") to the margins of color transitions that cover the colors of other separations that may shine through or empty regions ("flash lines").

There is no trapping on separated input documents, i.e. the trapping parameters have no effect.

Trapping can take place on the basis of vector data (graphics) or pixel data (images). It is possible to trap graphic to graphic, graphic to image and image to image. Trapping within images is not supported.

"Document" tab

"Document" group

"Override Settings from Document" option

Check this option if you want the trapping information that may be in the document to be overwritten by the trapping parameters set below.

"Add Settings as PDF Comment" option

All operations run by the "Trapping" engine are added as PDF annotations (comments) to the edited documents if you check this option.

"Retrap Trapped Pages" option

Activate this parameter if you want to retrap the documents with the parameters set below.

"PostScript Level 2, if possible" option

PostScript Level 2 does not support DeviceN color spaces correctly. This means that DeviceN color spaces are not reproduced correctly on PostScript Level 2 RIPs. If possible, traps are created without using the DeviceN color space when you enable this option.

"Limits" group

This group lets you specify restrictions regarding the complexity of page contents or runtime when you create trap lines.

"Maximum Size of Page Content" box and "When Maximum Size is Exceeded" parameter

In the automated mode (for example, during batch processing), this parameters prevent a long-running action from blocking job processing. You can set one of the following reactions if the size of the page content in a document exceeds a set data volume (MB):

b_cancel_small

Cancel with error:

The job is canceled and an error message issued.

b_warn_small

Continue with warning:

Processing continues; an alert message displays.

b_ignore_small

Ignore and continue:

This condition is ignored. Processing continues irrespective of the data volume.

Default: 10 MB.

"Maximum Number of Objects in Page Content" box and "When Maximum Number is Exceeded" parameter

This is where you can enter the maximum number of objects that a page may have.

Default: 10000 objects.

"Maximum Duration of Trapping" box and "When Maximum Duration is Exceeded" parameter

This is where you can enter the maximum time for trapping a document. When the set time is exceeded, the reaction follows the set rule.

Default: 10 minutes.