Plate Templates 

You will find shipped templates for standard plate templates in the "Standard" folder in the "Plate Templates" resource.

Create a folder as described in To create a group folder for your own custom plate tem­plate resources. Mark the new folder, display the context-sensitive menu and select "New Plate Tem­plate...". The Plate Template Editor displays and you can now define your own plate tem­plate.

Schemes 

You will find shipped templates for standard schemes in the "Standard" folder in the "Schemes" resource.

Create a folder as described in To create a group folder for your own custom schemes. Mark the new folder, display the context-sensitive menu and select "New Scheme...". The Folding Scheme Editor displays and you can now define your own scheme.

You also have the option of studying an existing scheme with the "Open Folding Sheet Animation" function. See also Folding Sheet Animation... .

IconNote00111.jpg

Note: Special folding schemes that begin with L* or S* are available for the Heidelberg Stahlfolder TH/KH-82-P, TX96 with Pallet Feeder PFX folding machines. These folding schemes follow a set naming scheme.

Marks 

Shipped marks are located in the "Marks" resource. You will find write-protected standard marks in the "Standard" folder. You can place these marks in an open job.

Create a folder as described in To create a group folder for your own custom marks. Mark the new folder, display the context-sensitive menu and select the appropriate marks editor. The fol­lowing marks editors are available: Marks Editor , Text Marks Editor , Ink Pickup Bar Editor , Color Control Bar Editor , Color Control Bar Special Editor , Marks Import Editor , Marks Import Editor (Line Mark) , Combi Marks Editor , and Barcode Editor .
You can create your own marks or edit imported marks using these editors.

On the "Marks" folder level, you can also import existing marks practically automatically by displaying the context-sensitive menu and selecting Marks Import Assistant  . This function is very helpful when updating marks.

You will find text marks in the "Report" folder. You can place these marks in the list window for output of HTML and/or PDF files. See "Save Table as HTML Report ...".

Papers (Printing Materials)

This resource allows you to work with the MDS. See MDS (Master Data Store) .

You will find shipped templates for standard papers in the "Standard" folder in the "Papers (Printing Materials)" resource.

Create a folder as described in To create a group folder for your own custom paper resources. Mark the new folder, display the context-sensitive menu and select "New Paper". The Paper (Printing Material) Editor  displays and you can now define your own paper (printing material).

When working with the MDS, you have a slightly different editor that is analog to the Printing Material Editor in the Prinect Cockpit (see Paper (Printing Material) - MDS Editor).

Page and Paper Sizes

You will find shipped templates for standard paper sizes in the "Standard" folder in the "Page and Paper Sizes" resource.

Create a folder as described in To create a group folder for your own custom page and paper sizes. Mark the new folder, display the context-sensitive menu and select "New Format". The Format Editor displays and you can now define your own page and paper size.

Plate layout

You will find a shipped template for a standard plate layout in the "Standard" folder in the "Plate Lay­out" resource.

Create a folder as described in To create a group folder for your own custom plate layout resources. Mark the new folder, display the context-sensitive menu and select "New Plate Layout". The Plate Layout Editor displays and you can now define your own plate layouts.

Customer Data

This resource allows you to work with the MDS. See MDS (Master Data Store) .

You will find shipped sample customers in the "Standard" folder in the "Customer Data" resource. You can use these customers to create a test job.

Create a folder as described in To create a group folder for your own customer data. Mark the new folder, display the context-sensitive menu and select "New Customer Data". The Customer Data Editor displays and you can now define your own customer data.

Output Parameter Sets

You will find shipped templates for standard output setups in the "Standard" folder in the "Output Parameter Sets" resource.

Create a folder as described in To create a group folder for your own output parameter sets. Mark the new folder, display the context-sensitive menu and select "New Output Parameter Set". The Output Parameter Set Editor  displays and you can now define your own output parameter sets.

User Data

This resource allows you to work with the MDS. See MDS (Master Data Store) .

In the "User Data" resource, you will find groups and users set by Prinect Signa Station for internal user administration. All groups and users are subject to certain permissions.

You can create, edit and delete users, provided that you have the necessary permissions.

Concept

Prinect Signa Station has its own user administration. This means that you can define and manage your users yourself in Prinect Signa Station.

User permissions in Prinect Signa Station basically control how resources are handled.

User data are managed locally by Prinect Signa Station. If there is a connection to an MDS server, the MDS is first queried for user data. Only if the user is unknown in the MDS is the search and login then local in Prinect Signa Station.

The following is applicable both for local and for Prinect user administration: The permissions of a user are defined solely by belonging to one of the following permission groups:

Group with administrator permissions

Group with Poweruser permissions

Group with user permissions

The permissions of the group are based on a hierarchy: administrator permissions have the most authority and guest permissions the least.

The following users are defined by default after installation:

Local user administration:

Predefined Users

User Name

Password

Permissions groups

Administrator

Signa

signa

local\Administrators

Prinect user administration:

Predefined Users

User Name

Password

Permissions groups

Administrator

PrePressAdministrator

?

MDS\PrePressAdministrators

Poweruser

PrePressPoweruser

?

MDS\PrePressPowerusers

User

PrePressUser

?

MDS\PrePressUsers

You must log in as administrator with "Signa" as your user name and "signa" as your password the first time you start Prinect Signa Station after installation. You then have permission to create users and assign them to the permission group desired.

Only "PrePress" users can log in at Prinect Signa Station.

Assigning Permissions

You assign user permissions in "Jobs & Resources > Resources & Machines > User Data".

You can create users with the context-sensitive menu in the relevant permission group. The following example will be used to describe the procedure.

Example: Creating and assigning a user to a permission group.

We will create the following user in this example:

User name: "HD_Admin"

Password: "Heidelberg"

Permission group: Administrator permissions

Local user administration

Creating a User

1.Mark "PrePress Administrators" in "User Data" and display the context-sensitive menu.

2.Click "New User Data..." to create the new user.

3.Type in "HD_Admin" as the user name and "Heidelberg" as the password twice and click "Save".
You will then see the new "HD_Admin" user in the list of defined "PrePress Administrators". The new "HD_Admin" user now has the permissions of the "PrePressAdministrators" group.

(4).You can change the password of every user. To do this, double-click the user in the user list, enter a new password twice and then click "Save".

(5).You can delete every user that you created. Mark the user and display the context-sensitive menu. Click "Delete User Data" to remove the user.

Assigning Different Permissions to a User

Let's take the new "HD_Admin" user from the above example. This user is just to have Poweruser per­missions instead of administrator permissions.

1.Mark the "HD_Admin" user.

2.Drag-and-drop the user to the "PrepressPoweruser" group.

Permissions table for Prinect Signa Station

Function

PrePress Administrators

PrePress Powerusers

PrePress Users

Resources

 

 

 

Create a new resource

Yes

Yes

Yes

Lock resources

All

All

No

Modify resources

All

All

One's own

Unlock resources

All

One's own

No

Copy locked resource

Yes

Yes

Yes

User administration (delete, change, set up)

All

No

No

User Login

A login dialog always appears for logging in to Prinect Signa Station.

To skip the login dialog, you can define in Prinect Signa Station which user will be logged in automat­ically when Signa Station launches.

In "File > Preferences > General > Default User", enable the check box and select a user.

User Logoff

The user currently logged in can log off at any time with "File > Logoff". A user must log off first before another user logs in.

Report Headers

You will find shipped templates for standard report headers in the "Standard" folder in the "Report Headers" resource.

Create a folder as described in To create a group folder for your own report headers. Mark the new folder, display the context-sensitive menu and select "New Report Header". The Report Templates Editor displays and you can now define your own report headers.

Sheet Optimization Setup

You will find shipped templates with setups for standard sheet optimization in the "Standard" folder in the "Sheet Optimization Setup" resource.

Create a folder as described in To create a group folder for your own optimization param­eters. Mark the new folder, display the context-sensitive menu and select "New Sheet Optimization Setup...". The Sheet Optimization Setup Editor  opens. This editor lets you define and save your own parameters of sheet optimization.