The "Quality" tab offers several quality reports of a selected operation.
•Operation Quality "Summary"
This report shows two evaluations:
·The OK sheet is compared with the wet ink set of the measuring device and assessed with regard to the deviations to the print standard.
·The production run sheets are compared with the OK sheet and assessed with regard to the deviations to the print standard.
•Operation Quality "Progress"
This report shows the measurement results over the entire print duration as they are visible to the operator of the colorimeter.
•Operation Quality "Zone Evaluation"
These reports contain the average, the maximum and the minimum Delta E, density and dot gain value for each ink zone.
To analyze the quality data, the following prerequisites must be met:
Quality report / |
Prinect Image Control I |
Prinect Image Control II |
Prinect Inpress Control & Prinect Axis Control II |
Prinect Axis Control I |
---|---|---|---|---|
Summary |
Not supported |
I13A and later |
S12B and later |
Not supported |
Trend: |
V5.1 and later |
I11A and later |
S10A and later |
Not supported |
Trend: |
V5.1 and later |
I11A and later |
S11B and later |
Not supported |
Trend: |
No restriction |
I13A and later |
S12B and later |
Not supported |
Zone analysis: |
V5.1 and later |
I11A and later |
S10A and later |
Not supported |
Zone analysis: |
V5.1 and later |
I11A and later |
S11B and later |
Not supported |
Why are measured values not shown although current software versions are present?
Storage period of the color reports exceeded
If measured data should not display despite the latest software versions, it is possible that they were already deleted from Analyze Point. See Storage Period of Reports.
Special features with Prinect Inpress Control
With Prinect Inpress Control, measured data for dot gain may not be available for an operation. In this case, the last available measured data for dot gain are shown in the diagram. The reasons for no measured data may be:
•It is a short production run.
Prinect Inpress Control measures quality every 400 sheets, and in short production runs quality may not be measured during an operation.
•Dot gain was not measured by the machine operator.
When quality is measured, the machine operator must enable dot gain measurement manually. As of V14B, the operator can enable "Apply measured value for dot gain" so that dot gain is measured automatically.