analyze_point_productivity_16

The time index (1) is one of the three OEE indicators that has been mentioned earlier. See OEE Index. The higher the average time indicator, the more productive you will be with your press, provided that little waste is generated.

Let us assume that your press is switched on at 8:00 in the morning and switched off at 4:00 in the afternoon. During a period of 8 hours the press is always ready for production. A time index of 50% in this case means that the press only produced good or waste sheets for 4 hours in a possible period of 8 hours.

The "Time index" diagram displays the following information:

The average time index for each day (2).

The average speed index for the entire month (3).

The calculated OEE index (4). See OEE Index.